meanining of a 10 ton boiler

CONVERSION OF BOILER IN KG/H AND KW - cni.co.th

CONVERSION OF BOILER IN KG/H AND KW (Approximate) G.B. and U.S.A. Steam from and at 100°C Boiler HP Kg/h 2.26MJ/kg Metric System Steam from 0°C to 100°C Kg/h 2.26MJ/kg Power In kW 1 5 10 15 20 30 40 50 60 70 80 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 15.65 78 156 235 313 470 626 783 940 1096 1252 1566 2350 3130 3915 4700 5480

Get A Quote

Boilerplate | Definition of Boilerplate by Merriam-Webster

Boilerplate definition is - syndicated material supplied especially to weekly newspapers in matrix or plate form. How to use boilerplate in a sentence. boilerplate in Print

Get A Quote

Back to Basics: Venting for Gas-Fired Boilers | 2003-06-04

Jun 04, 2003 · Deduct 10% from the Btu/hr capacity of the vent for each additional 90-degree elbow. A Category I vent system works by allowing heated flue products to rise vertically, so the vent pipe must rise vertically from the boiler vent connection as soon as possible. You should also limit the length of the horizontal flue pipe.

Get A Quote

Commonly Used HVAC Formulae and Conversions

1 ton refrigeration = 12,000 Btu/h = 200 Btu/min 1 watt = 3.412 Btu/h 1 horsepower = 2545 Btu/h 1 lb = 7000 grains 1 ft (head) = 0.433 psi 1 square foot EDR (equivalent direct radiation) = 240 Btu 1 boiler horsepower = 33,479 Btu/h No. of air changes (N) =60 cfm/ft3

Get A Quote

HVAC Sizing | Air Conditioner Sizing | Heater Sizing

One ton is 12,000 BTU. So a 2.5-ton system would be 2.5 tons x 12,000 BTU/ton = 30,000 BTU. Easy mistakes to make when sizing heaters

Get A Quote

Controlling TDS in the Boiler Water | Spirax Sarco

A boiler water sample has an unneutralised conductivity of 5 000 μS/cm at 25°C. What is the conductivity of the boiler water at 10 bar g?ses at the rate of approximately 2% (of the value at 25°C) for every 1°C increase in temperature. This can be written as:

Get A Quote

BOILER SELECTION CONSIDERATIONS - Cleaver-Brooks

Boiler horsepower (BHP) is a measure of boiler energy output. One boiler horsepower (from and at 212 °F): BHP = 34.5 lbs/hr BHP = 33,472 Btu/hr BHP = 9.8 kW BHP should not be confused with other horsepower measurements. Boiler Trim: Accessories added to the boiler, such as auxiliary low water cutoff, special tappings, special gas

Get A Quote

Lay-up of Heating Boilers

The steps of preparing a boiler for wet lay-up are essentially the same for dry lay-up. The exception is when a boiler is closed and prepared to be filled with water and water treatment chemicals. Perform dry lay-up steps 1-6 (except do not swab the fireside with mineral oil) and then follow with step 7 below.

Get A Quote

Steam Capacity Conversion Table | Industrial Controls

250 BHP Boiler. 250(BHP) x 0.069 (gpm/BHP) x 10 (min) x 1.33(SF) = 229.425 . Because of the 10 minute multiplier used in calculating a boiler feed pump receiver for boilers 200 BHP and over, a very fast sizing estimate can be done by simply stating that 1 BHP = 1 gallon of gross receiver capacity.

Get A Quote

Boiler Ratings Explained - Heating Help

Jun 18, 2014 · Then, in 1967, they further reduced the Pickup Factor from 1.33 to 1.15, but only for hot water boilers. They let the factor for steam boiler sizing remain at 1.33 because steam piping is bigger than hot water piping. This is because steam is bigger than water. There's one problem here, though. Steam pipes contain hardly any water. But don't

Get A Quote

meaning of boiler capacity

what is the capacity of oil-fired boiler - unic.co.in. what is the capacity of oil-fired boiler. Installing a standard boiler (80%-85% annual fuel utilization efficiency) typically costs about $2,500-$5,000 for a gas-fired model and $3,000-$6,500 for an oil-fired unit (generally used in areas without municipal gas lines).

Get A Quote

BOILER CONTROLS &BOILER CONTROLS & INSTRUMENTATION

fed to the boiler should be controlled tofed to the boiler should be controlled to give the necessary quantity of steam. the steam demand increase or decrease will be indicated by the boiler outlet pressureindicated by the boiler outlet pressure. hence combustion control is essentially a control to keep the boiler outlet pressure

Get A Quote

F & A Rating Of Boiler - Student - Cheresources.com Community

Mar 14, 2008 · F & A Rating Of Boiler - posted in Student: we need to calculate the boiler capacity based on F&A rating.Our consumption is 2500 kg/hr steam at 17kg/cm2(g)We provide feed water at 100degC to the boiler drum.please suggest, how to arrive at F&A rating.Thanks in Advance.Regards,raghav.

Get A Quote

What do you understand by a 2-ton boiler? - Quora

If we made reference to a 10 tonne boiler or a 3 tonne boiler it was usually a shortening of its equivalent evaporative capacity. In other words, I believe that your reference to a 2 tonne boiler means a boiler that has a maximum steaming capacity of 2 tonnes of steam per hour from and at 100 degrees celsius and at atmospheric pressure.

Get A Quote

Industrial boiler technology for beginners

How an industrial boiler system works The heart of an industrial boiler system is a hot water or steam boiler operated with a certain kind of fuel. The boiler heats up or evaporates the water inside it, which is then transported to the consumers via pipe systems. In case of hot water the transport energy is generated by

Get A Quote